Technical parameters zf700
Illumination (adjustable) 40000-180000lux
Average life of bulb ≥ 1500h
Color temperature 4500k ± 250K
Display index ≥ 97%
Focus depth (adjustable) 1200mm
Spot diameter (adjustable) 160-280mm
Brightness adjustment 10 gears continuous adjustment
Power consumption (W) 150
The head temperature of the operator is less than 2 ℃
Automatic switching of main and auxiliary lights < 0.2S
Power supply voltage AC100-240V 50 / 60Hz
Product features:
★ ZF series reflective surgical shadowless lamp is widely used for lighting needs of various surgical occasions,
It is the ideal lighting equipment for modern operating room.
★ the whole reflection optical system created by CAD / CAM technology is specially designed by experts
Process + oxidation + electrolysis technology treatment, the annual service life is increased by 5 times, and the oxidation film is not faded or removed.
Irradiation depth ≥ 1200mm; color temperature compensation technology is used to improve color reducibility, which is more suitable for
Lighting for large and complex operations such as brain surgery and thoracic surgery.
★ microcomputer digital control, with ten segment brightness selection, illumination memory function and width
Voltage operating characteristics, stable operation within the voltage range of ac160v-250v, strong anti-interference ability.
★ totally enclosed and streamlined lamp body design, fully meeting today's operating room disinfection and high standards
Laminar flow requirements.
★ the light panel is molded by PC (bullet proof glass) to make the light softer and safer
Reliable.
★ the focusing system has a delicate structure, which can replace the bulb quickly and conveniently. The detachable handle coat,
It can be sterilized at high temperature (≤ 134 ℃).
★ it has automatic switching function of backup bulb. When the main lamp is damaged, the auxiliary lamp is within 0.2S
Automatic lighting, main and auxiliary lights failure indication on the handle panel, prompt for timely replacement after operation.
The soft start device is used to prolong the service life of the bulb effectively and to import long life halogen tungsten.
Bulb, bulb life ≥ 1500 hours.
★ key components are all international famous brand products, stable and reliable operation, flame-retardant materials resistant
Temperature safety, in accordance with IEC standards.
★ equipped with light balance arm suspension system, six groups of joint linkage, light movement, stable positioning, 360 ° all-round design, there are two kinds of imported and domestic products for users to choose from, and
It can meet the needs of different height and angle in operation.
Lens design system of new standard
★ lamp shell: high quality aluminum plate material, with high strength, high heat dissipation, wear resistance and corrosion resistance
Performance.
★ reflector: the surface adopts optical expert technology, and the mirror adopts special technology + oxidation+
New electrolysis technology, more than 5 times longer than coating reflection system life, no fading, no oxidation
Film, excellent depth lighting, fully meet your requirements.
★ polyhedral mirror reflection system, the lens reaches more than 5280, making the operation area truly invisible,
Advanced color temperature compensation technology provides more close to the color temperature of natural sunlight and uniform coverage
The entire surgical area.
Good laminar flow purification, disinfection, mirror design and backup bulb replacement
★ fully enclosed streamline lampshade is designed carefully according to the principle of aerodynamics, which is beneficial to hands
The application of laminar flow purification and disinfection in operating room can reduce the risk of surgical infection. Light transmitting glass at the bottom of lamp cap
The glass is made of anti vibration and anti disinfectant materials, which is durable, easy to clean and free from radiation
It is affected by wiping and long-term use. The lamp holder handle can push and pull up and down, rotate and adjust the lamp holder
After operation, it can be easily removed for solution immersion or high temperature pressure disinfection.
★ when changing the bulb, gently press the locking system, the replacement process is simple.
Digital integrated circuit control system
★ the power switch, brightness adjustment and auxiliary lamp detection are practical and integrated, with ten sections of light
Degree selection and brightness memory function, self indicating LED brightness.
★ the panel has the main lamp fault indicator to remind the operator to replace the bulb in time after the operation. ★ it has wide voltage operation characteristics, stable operation within the voltage range of ac160v-250v, resistant to
Strong interference ability.
Signal indication system
★ if the light source fails during the operation, the signal lamp will immediately display the switching setting of the operation lamp
Spare bulb mode, and replace the faulty bulb calmly after operation.
★ to eliminate the risk, the automatic switching system of spare light bulb, one of the most dangerous during the operation is the hand
The bulb may fail during the operation. The automatic switching system via the spare light bulb will
Automatic switching within 0.2 seconds will automatically light up, and the light intensity and operation area will not be affected at all
Impact.
High efficiency filter system
★ experts recommend thermal energy filtering technology to make 99.5% of infrared rays filtered out and the injured area of patients
The temperature rise is 11 ℃ (international standard 12 ℃), so there is no risk of water evaporation in the operation area.
Universal joint system
★ the spring arm suspension system has six sets of universal joints and 360 ° joint linkage in all directions
Accurate positioning, completely solve the drift phenomenon.
Natural operation color temperature
★ the color temperature correction system designed by experts provides a color temperature close to 4500k of natural sunlight,
Ensure that the surgeon can clearly and accurately identify the color of vascular tissue and nerve bundle in the operation area.
Configuration list
1. Zf700 lamp head, dimming system 1 set
2. 4 universal wheels
3. 4 bulbs (24V / 150W)
4. 2 disinfection handles
5. 1 set of Allen wrench
6. Balance arm 1 set
7. Column 1 set
8. Base (including switching power supply) 1 set
9. 1 Certificate
10. 1 operation manual